    Overview
    • Remote start capability built in for HD series - remote switch not included.

    • Exhaust Kit includes piping from pump with P-Trap, drain and 23 inches schedule 80 1 ¼ inch pipe. Inlet Kit includes hose and fittings from air water separator to vacuum pump

    • As with all dry vac suction systems a drip leg is recommended on the exhaust line to prevent condensate return to the pump and is included with all systems.

    • This is the maximum number of users during normal working conditions (includes diversity). for 100% redundancy (back up / spare) do not count 2nd motor in calculation

    • All models adjustable from 5” Hg to 25” Hg. Recommnded set point 15” Hg to 20” Hg

    • Noise level measured at 3.5 feet with inlet and exhaust piping connected.

    • Weight excludes packaging for shipping.

    • Optional 3 Phase 230 / 460 / 575 - 220v single phase models include a buck boost with each pump to adjust voltage to 220 volts +/- 5 volts

    • Systems come complete with: air/water separator, auto drain kit, quick disconnect hose kit, inlet piping kit and exhaust piping kit. 

    • Larger capacity and continuous run air water separators are compatible with HD systems. 

        • Models & Specifications

      Model 3HD 4.40P
      Users 3 x 4
      Operatories 10 - 18
      hp 3 x 2
      Amps 3 x 9.5
      Voltage 220V, 1 Phase
      dB 74
      Dimensions 26" x 18" x 72"
      Lbs 3 x 121